 TLL.540.
Vishay Telefunken
Low Current LED in o 5 mm Tinted Diffused Package
Color High efficiency red Yellow Green Type TLLR540. TLLY540. TLLG540. Technology GaAsP on GaP GaAsP on GaP GaP on GaP Angle of Half Intensity o 25 25 25
Features
D D D D D D
Low power consumption High brightness CMOS/MOS compatible Specified at IF = 2 mA Luminous intensity categorized Yellow and green color categorized
96 11505
Applications
Low power DC circuits
Absolute Maximum Ratings
Tamb = 25_C, unless otherwise specified TLLR540. ,TLLY540. ,TLLG540. , Parameter Reverse voltage DC forward current Surge forward current Power dissipation Junction temperature Operating temperature range Storage temperature range Soldering temperature Thermal resistance junction/ambient Test Conditions Tamb 90C tp 10 ms Tamb 90C Symbol VR IF IFSM PV Tj Tamb Tstg Tsd RthJA Value 6 7 0.15 20 100 -40 to +100 -55 to +100 260 500 Unit V mA A mW C C C C K/W
t 5 s, 2 mm from body
Document Number 83030 Rev. A2, 04-Feb-99
www.vishay.de * FaxBack +1-408-970-5600 1 (7)
TLL.540.
Vishay Telefunken Optical and Electrical Characteristics
Tamb = 25_C, unless otherwise specified High efficiency red (TLLR540. ) Parameter Luminous intensity y Dominant wavelength Peak wavelength Angle of half intensity Forward voltage Reverse voltage Junction capacitance Test Conditions IF = 2 mA, IVmin/IVmax 0.5 IF = 2 mA IF = 2 mA IF = 2 mA IF = 2 mA IR = 10 mA VR = 0, f = 1 MHz Type Symbol TLLR5400 IV TLLR5401 IV ld lp VF VR Cj Min 0.63 1 612 Typ 1.2 2 635 25 1.9 20 50 Max Unit mcd mcd nm nm deg V V pF
625
2.4
6
Yellow (TLLY540. ) Parameter Luminous intensity y Dominant wavelength Peak wavelength Angle of half intensity Forward voltage Reverse voltage Junction capacitance Test Conditions IF = 2 mA, IVmin/IVmax 0.5 IF = 2 mA IF = 2 mA IF = 2 mA IF = 2 mA IR = 10 mA VR = 0, f = 1 MHz Type Symbol TLLY5400 IV TLLY5401 IV ld lp VF VR Cj Min 0.63 1 581 Typ 1.2 2 585 25 2.4 20 50 Max Unit mcd mcd nm nm deg V V pF
594
2.9
6
Green (TLLG540. ) Parameter Luminous intensity y Dominant wavelength Peak wavelength Angle of half intensity Forward voltage Reverse voltage Junction capacitance Test Conditions IF = 2 mA, IVmin/IVmax 0.5 IF = 2 mA IF = 2 mA IF = 2 mA IF = 2 mA IR = 10 mA VR = 0, f = 1 MHz Type TLLG5400 TLLG5401 Symbol IV IV ld lp VF VR Cj Min 0.63 1 562 Typ 1.2 2 565 25 1.9 20 50 Max Unit mcd mcd nm nm deg V V pF
575
2.4
6
www.vishay.de * FaxBack +1-408-970-5600 2 (7)
Document Number 83030 Rev. A2, 04-Feb-99
TLL.540.
Vishay Telefunken Typical Characteristics (Tamb = 25_C, unless otherwise specified)
25 PV - Power Dissipation ( mW ) IF - Forward Current ( mA ) 100 High Efficiency Red 10
20
15
10 5 0 0 20 40 60 80 100
1
0.1 0
95 10050
tp/T=0.001 tp=10ms 1 2 3 4 5
95 10063
Tamb - Ambient Temperature ( C )
VF - Forward Voltage ( V )
Figure 1 Power Dissipation vs. Ambient Temperature
10 Iv rel - Relative Luminous Intensity IF - Forward Current ( mA )
Figure 4 Forward Current vs. Forward Voltage
2.0 High Efficiency Red 1.6
8
6
1.2
4 2 0 0 20 40 60 80 100
0.8 0.4 IF=2mA 0 0 20 40 60 80 100
95 10064
Tamb - Ambient Temperature ( C )
95 10051
Tamb - Ambient Temperature ( C )
Figure 2 Forward Current vs. Ambient Temperature
0 Iv rel - Relative Luminous Intensity 10 20 30
Figure 5 Rel. Luminous Intensity vs. Ambient Temperature
2.4 Iv rel - Relative Luminous Intensity High Efficiency Red 2.0 1.6 1.2 0.8 0.4 0
40 1.0 0.9 0.8 0.7 50 60 70 80 0.6 0.4 0.2 0 0.2 0.4 0.6
10
96 11490
20 0.5
50 0.2
100 0.1
200 0.05
500 0.02
IF(mA) tp/T
95 10060
1
Figure 3 Rel. Luminous Intensity vs. Angular Displacement
Figure 6 Rel. Lumin. Intensity vs. Forw. Current/Duty Cycle
Document Number 83030 Rev. A2, 04-Feb-99
www.vishay.de * FaxBack +1-408-970-5600 3 (7)
TLL.540.
Vishay Telefunken
100 Iv rel - Relative Luminous Intensity Iv rel - Relative Luminous Intensity High Efficiency Red 10 2.0 Yellow 1.6
1.2
1
0.8 0.4 0
0.1
0.01 0.1
95 10061
1
10
100
95 10054
0
20
40
60
80
100
IF - Forward Current ( mA )
Tamb - Ambient Temperature ( C )
Figure 7 Relative Luminous Intensity vs. Forward Current
Figure 10 Rel. Luminous Intensity vs. Ambient Temperature
2.4
1.2 Iv rel - Relative Luminous Intensity High Efficiency Red 1.0 0.8 0.6 0.4 0.2 0 590
95 10040
Iv rel - Relative Luminous Intensity
Yellow 2.0 1.6 1.2 0.8 0.4 0
610
630
650
670
690
9611590
10 1
20 0.5
50 0.2
100 0.1
200 0.05
500 0.02
IF(mA) tp/T
l - Wavelength ( nm )
Figure 8 Relative Luminous Intensity vs. Wavelength
Figure 11 Rel. Lumin. Intensity vs. Forw.Current / Duty Cycle
100 Iv rel - Relative Luminous Intensity
100 IF - Forward Current ( mA ) Yellow 10
Yellow 10
1
1
0.1
0.1 0
95 10053
tp/T=0.001 tp=10ms 1 2 3 4 5
0.01 0.1
95 10062
1
10
100
VF - Forward Voltage ( V )
IF - Forward Current ( mA )
Figure 9 Forward Current vs. Forward Voltage
Figure 12 Relative Luminous Intensity vs. Forward Current
www.vishay.de * FaxBack +1-408-970-5600 4 (7)
Document Number 83030 Rev. A2, 04-Feb-99
TLL.540.
Vishay Telefunken
1.2 Iv rel - Relative Luminous Intensity Iv rel - Relative Luminous Intensity Yellow 1.0 0.8 0.6 0.4 0.2 0 550
95 10039
2.4 Green 2.0 1.6 1.2 0.8 0.4 0 570 590 610 630 650
96 11591
10 1
20 0.5
50 0.2
100 0.1
200 0.05
500 0.02
IF(mA) tp/T
l - Wavelength ( nm )
Figure 13 Relative Luminous Intensity vs. Wavelength
100 Green 10 Iv rel - Relative Luminous Intensity IF - Forward Current ( mA )
Figure 16 Rel. Lumin. Intensity vs. Forw.Current / Duty Cycle
100 Green 10
1
1
0.1
0.1 0
95 10056
tp/T=0.001 tp=10ms 1 2 3 4 5
0.01 0.1
95 10059
1
10
100
VF - Forward Voltage ( V )
IF - Forward Current ( mA )
Figure 14 Forward Current vs. Forward Voltage
1.6 Iv rel - Relative Luminous Intensity
Figure 17 Relative Luminous Intensity vs. Forward Current
1.2 Iv rel - Relative Luminous Intensity Green 1.0 0.8 0.6 0.4 0.2 0 520
95 10038
Green 1.2
0.8
0.4 IF=2mA 0 0 20 40 60 80 100
540
560
580
600
620
95 10057
Tamb - Ambient Temperature ( C )
l - Wavelength ( nm )
Figure 15 Rel. Luminous Intensity vs. Ambient Temperature
Figure 18 Relative Luminous Intensity vs. Wavelength
Document Number 83030 Rev. A2, 04-Feb-99
www.vishay.de * FaxBack +1-408-970-5600 5 (7)
TLL.540.
Vishay Telefunken Dimensions in mm
95 10916
www.vishay.de * FaxBack +1-408-970-5600 6 (7)
Document Number 83030 Rev. A2, 04-Feb-99
TLL.540.
Vishay Telefunken Ozone Depleting Substances Policy Statement
It is the policy of Vishay Semiconductor GmbH to 1. Meet all present and future national and international statutory requirements. 2. Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safety of our employees and the public, as well as their impact on the environment. It is particular concern to control or eliminate releases of those substances into the atmosphere which are known as ozone depleting substances ( ODSs ). The Montreal Protocol ( 1987 ) and its London Amendments ( 1990 ) intend to severely restrict the use of ODSs and forbid their use within the next ten years. Various national and international initiatives are pressing for an earlier ban on these substances. Vishay Semiconductor GmbH has been able to use its policy of continuous improvements to eliminate the use of ODSs listed in the following documents. 1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments respectively 2 . Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental Protection Agency ( EPA ) in the USA 3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C ( transitional substances ) respectively. Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting substances and do not contain such substances.
We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All operating parameters must be validated for each customer application by the customer. Should the buyer use Vishay-Telefunken products for any unintended or unauthorized application, the buyer shall indemnify Vishay-Telefunken against all claims, costs, damages, and expenses, arising out of, directly or indirectly, any claim of personal damage, injury or death associated with such unintended or unauthorized use. Vishay Semiconductor GmbH, P.O.B. 3535, D-74025 Heilbronn, Germany Telephone: 49 ( 0 ) 7131 67 2831, Fax number: 49 ( 0 ) 7131 67 2423
Document Number 83030 Rev. A2, 04-Feb-99
www.vishay.de * FaxBack +1-408-970-5600 7 (7)


▲Up To Search▲   

 
Price & Availability of TLLY540

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X